Motronic M 1.5.4 Quick Check F0:DATA LIST
| No. | TECH 1-Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 41 | 02 BLM PART THR. | X 20 SE, X 22 XE engine only: | |||
| Engine running at partial load range, operating temperature | 118 to 138 STEPS | 13, 38, 39 | - |