| Test | TECH 1 | Notes | Nominal Values | Pin | Possible |
|---|---|---|---|---|---|
| Step | Display | Trouble | |||
| No. | Codes | ||||
| 27 | A/C CUTOFF RELAY | Engine at idle speed, | INACTIVE 12V | 23/24 | 87, 88 |
| Actuate air conditioning | |||||
| switch |
Trouble-shooting Nominal Value: Cause of Fault:
(If nominal value is not attained)
Note:
A/C CUTOFF RELAY is actuated by the Motronic and switches the compressor off at over 6000 rpm.
· Check for passage way between 0 W
Motronic control unit Ter. 23 and
A/C CUTOFF RELAY Ter. 86
· Ignition ON
Ter. 85 (+) to ground Battery voltage · Lead interruption between
fuse F 28 and A/C CUTOFF RELAY
Ter. 85
Ter. 86 to ground · Lead interruption between
A/C CUTOFF RELAY Ter. 86 and
· Trouble codes 87, 88 see table 2 Motronic control unit Ter. 23
· Relay K 23 defective
· Control unit defective