Motronic M 1.5.4 F2:TROUBLE CODE TABLE
| Trouble Code | Information Sensor Cause of Fault | Data List No. | Trouble Code Storage when |
|---|---|---|---|
| 15 | COOLANT TEMP. | ||
| VOLTAGE HIGH | 06 | · Intake air temperature greater than -20 °C (-4 °F) |
· Coolant temperature less than -35.4 °C (-31.7 °F) (Short circuit to voltage or circuit interruption)
Replacement value:
· Intake air temperature greater than 0.4 °C (32.7 °F): 101 °C (214 °F)
· Intake air temperature less than 0.4 °C (32.7 °F): the intake air temperature is taken as replacement value for 180 s after starting the engine, and after that back to 101 °C (214 °F).
Effect:
| · The learn functions (oxygen sensor control, idle air control and knock control) are blocked and the last valid values are used for calculation. |