Contents Section: Fuel Injection Systems All sections

F6:adjustments 02 Blm Reset Opel Frontera A

Motronic M 1.5.4 System- Modification F6:ADJUSTMENTS

02 BLM RESET

Conditions for CheckingNominal Value

X 20 SE, X 22 XE engine only :

Affected Terminals: -

Possible Trouble Codes: -

Engine running at idle speed

Engine throttle valve CLOSED (accelerator pedal in idle position)

Vehicle stationary

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the diagnostic tester display.

02 INTEGRATOR

02 BLM IDLE THR.

Note:

In this mode, it is possible to reset the above mentioned engine learn parameters using the arrow keys, i.e. to set them to 128 steps. The learn parameters indicate the shortterm and longterm behaviour of the oxygen sensor control circuit. If a fault occurs in this circuit these values taper off upwards or downwards. If the fault in the oxygen sensor control circuit is eliminated, the learn parameters return to the normal value of 128 steps. This process may however take several minutes. For this reason, it is possible to reset the parameters directly to the normal value of 128 steps using this diagnostic tester mode. The engine should then be run for some time in spite of this, to check that the oxygen sensor control circuit has been correctly repaired. The reset is triggered by the ARROW UP key. In addition, the various data list parameters can be displayed via the YES and NO keys. Key F9 can be used to store data as in the snapshot mode.128 steps
128 steps