| Test | TECH 1 | Notes | Nominal Values | Pin | Possible |
|---|---|---|---|---|---|
| Step | Display | Trouble | |||
| No. | Codes | ||||
| 03 | EXHAUST CODING | Ignition ON | 20/19 | - | |
| Closed loop systems | US 5V | ||||
| Open loop systems | ECE 0V |
Trouble-shooting: Nominal Value: Cause of Fault:
(If nominal value is not attained)
· Remove control unit plug Closed loop systems: · Incorrect wiring harness installed
cable cover Ter. 20 unoccupied,
5V
· Ignition ON Open loop systems: · Control unit defective
Ter. 20 grounded,
· Check Ter. 20 at control unit 0V
optically and with multimeter
Note: To remove the control unit plug cable cover, 3 bolts must be loosened and the cover pulled off upwards.
When doing this, do not disconnect the control unit from the wiring harness if possible, as this may delete stored trouble codes.