Table 2, Trouble Codes
Trouble
| code |
Information Sensor
Cause of Fault
Remedy in F0:DATA LIST
| No. |
|---|
| Trouble Code Storage when... |
| Remarks |
| 73 |
| MASS AIR FLOW SENSOR VOLTAGE LOW |
| 08 |
· Engine speed < 2520 rpm
· Short circuit to ground in signal lead of mass air flow meter
(Ter.3 on plug of mass air flow meter)
If trouble code 73 was recognized, the control unit calculates for the load signal with a replacement characteristic curve dependent on the engine speed and throttle valve angle. If the throttle valve potentiometer is also defective, the following replacement values are used for calculation:
For engine speed < 1520 rpm with load signal 2.0 ms For engine speed > 1520 rpm with load signal 4.5 ms