Table 2, Trouble Codes
Trouble
| Code | Information Sensor | Remedy in | |
|---|---|---|---|
| F0:DATA LIST | |||
| Cause of Fault | No. | Trouble Code Storage when ... | |
| Remarks | |||
| 13 | O2 SENSOR | 36, 37, 38, 39, | · Oxygen sensor voltage is in range |
| OPEN CIRCUIT | 40 | C 20 XE: 380 to 590 mV | |
| C 25 XE: 350 to 550 mV | |||
| for longer than 2.5 sec. | |||
| (circuit interruption, oxygen sensor defective) | |||
| The trouble code is stored if | |||
| (conditions must be fulfilled consecutively): | |||
| 1.) Coolant temperature higher than 70 °C/1 68 °F | |||
| 2.) Condition 1.) fulfilled for 3 min | |||
| 3.) Load signal greater than 1.5 ms | |||
| 4.) After conditions 1.) to 3.) are fulfilled, waiting period of 5 s elapsed | |||
| 5.) Trouble code 73 or 74 not recognized | |||
| Replacement value: | |||
| The control unit takes 450 mV as replacement value. | |||
| The oxygen sensor control is switched off. |