C-28, Torque Control Circuit
| C-28, Torque Control Circuit |
| Test | Work Order Description | Nominal Value |
| T01 | Check: Short to Voltage/Ground/Interruption of Signal Circuit | |
| Ignition OFF Disconnect wiring harness connector from: K85 Control Unit - Automatic Transmission Connect fused jumper wire to: K85 Control Unit - Automatic Transmission Wiring Harness Connector (wiring harness side) Terminal 5 & K85 Control Unit - Automatic Transmission Wiring Harness Connector (wiring harness side) Terminal 7 Engine idling Accelerator pedal not actuated Diagnostic Tester Data List Parameter TORQUE CONTROL | 55 ... 60 % |
| Yes: E01 | No: T02 |
| T02 | Check: Short to Voltage/Ground/Interruption of Signal Circuit | |
| Ignition OFF Disconnect wiring harness connector from: K85 Control Unit - Automatic Transmission Connect fused jumper wire to: K85 Control Unit - Automatic Transmission Wiring Harness Connector (wiring harness side) Terminal 5 & K85 Control Unit - Automatic Transmission Wiring Harness Connector (wiring harness side) Terminal 7 Engine idling Accelerator pedal not actuated Diagnostic Tester Data List Parameter TORQUE CONTROL | greater than 60 % |
| Yes: E02 | No: E03 |
| C-28, Torque Control Circuit |
| Result | Cause Of Fault |
| E01 | Defective component: K85 Control Unit - Automatic Transmission |
| |
| E02 | Short circuit to ground between: K69 Control Unit - Simtec Wiring Harness Connector (wiring harness side) Terminal 6 & K85 Control Unit - Automatic Transmission Wiring Harness Connector (wiring harness side) Terminal 5 or Defective component: K69 Control Unit - Simtec |
| |
| E03 | Short circuit to voltage/interruption of circuit between: K69 Control Unit - Simtec Wiring Harness Connector (wiring harness side) Terminal 6 & K85 Control Unit - Automatic Transmission Wiring Harness Connector (wiring harness side) Terminal 5 or Defective component: K69 Control Unit - Simtec |
| |