F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 28 | ENGINE SP. PULSE | Ignition ON | |||
| Engine running at idle speed | INACTIVE |
alternating between
ACTIVE and
INACTIVE
| - | 43, 19 |
Notes on Trouble-shooting:
| Nominal Value: | Cause of Fault: |
· Ignition OFF
· Using multimeter, check from plug for instrument panel
Astra-F:
X 8
Vectra / Cavalier / Calibra:
X 11/ Ter. 3
to control unit K 61/Ter. 43
| for continuity | ||
|---|---|---|
| approx. 0 W | · Short circuit or lead interruption from plug to instrument panel approx. 0 |
Astra-F:
X 8 / Ter. 2
Vectra / Cavalier / Calibra:
X 11 / Ter. 3
to control unit K 61 / Ter. 43
Instrument defective
Control unit K 61 defective