Remove
- 1. Disconnect harness connector (3) from mass air flow (MAF) meter
- 2. Release cover (2) from air cleaner assembly • Release 4x screw, then move to one side
- 3. Remove air cleaner element from air cleaner assembly
- 4. Release outlet hose (1) from air cleaner assembly • Release clip
- 5. Release harness for MAF meter from air cleaner assembly • Release clip using suitable tool
- 6. Remove air cleaner assembly from battery tray and upper front panel • Remove 2x bolt (4) • Pull up to release 2x locator from battery tray
- 7. Remove glow plug control unit (1) from battery tray • Slide off • Disconnect harness connector
Install
- 8. Install new glow plug control unit (1) to battery tray • Connect harness connector • Slide on
- 9. Install air cleaner assembly to battery tray and upper front panel • Push down to secure 2x locator to battery tray • Install 2x bolt (4)
- 10. Secure harness for MAF meter to air cleaner assembly • Secure clip
- 11. Secure outlet hose (1) to coolant expansion tank to air cleaner assembly • Secure clip
- 12. Install air cleaner element to air cleaner assembly
Note. Before installing the air cleaner element, remove all debris from the air cleaner assembly.
- 13. Secure cover (2) to air cleaner assembly • Secure 4x screw
- 14. Connect harness connector (3) to MAF meter