Contents Wiring diagrams Section: Engine Control and Fuel System - D13A All sections

Air Cleaner Element Replacement Opel Agila B

Remove

  1. 1. Disconnect harness connector from mass air flow meter
  2. 2. Release cover (2) from air cleaner assembly • Disconnect hose from cover – Release clip • Release 4x screw (1)
  3. 3. Remove air cleaner element from air cleaner assembly

Install

  1. 4. Install new air cleaner element to air cleaner assembly

Note. Before installing the air cleaner element, remove all debris from the air cleaner assembly.

  1. 5. Install cover (2) to air cleaner assembly • Secure 4x screw (1) • Connect hose to cover – Secure clip
  2. 6. Connect harness connector to mass air flow meter