Contents Wiring diagrams Section: Engine Control and Fuel System - D13A All sections

Air Cleaner Assembly Replacement Opel Agila B

Remove

  1. 1. Disconnect harness connector (3) from mass air flow (MAF) meter
  2. 2. Disconnect intake hose from air cleaner assembly (2) • Release clip
  3. 3. Release hose (1) from air cleaner assembly • Release clip
  4. 4. Release harness for MAF meter from air cleaner assembly • Release clip
  5. 5. Remove air cleaner assembly from battery tray and upper front panel • Remove 2x bolt (4) • Pull up to release 2x locator from battery tray
  1. 6. Remove MAF meter from air cleaner assembly • Remove 2x bolt

Install

  1. 7. Install new seal ring (1) to MAF meter
  1. 8. Install MAF meter to air cleaner assembly • Install 2x bolt
  2. 9. Install new air cleaner assembly (2) to battery tray and upper front panel • Push down to secure 2x locator to battery tray • Install 2x bolt (4)
  3. 10. Secure harness for MAF meter to air cleaner assembly • Secure clip
  4. 11. Secure hose (1) to air cleaner assembly • Secure clip
  5. 12. Connect harness connector (3) to MAF meter
  6. 13. Connect intake hose to air cleaner assembly • Secure clip