Remove
- 1. Disconnect harness connector (1) from DPF differential pressure sensor • Release harness connector lock
- 2. Release hose (2) from DPF sensor • Release clip • Install new blanking plug
- 3. Remove DPF sensor from fuel pipe assembly • Remove bolt
Install
- 4. Install new DPF sensor to fuel pipe assembly • Install bolt
- 5. Secure hose (2) to DPF sensor • Remove blanking plug • Secure clip
- 6. Connect harness connector (1) to DPF sensor • Secure harness connector lock