Technical Data
Cooling System
| Engine | C 20 SEL | |||
|---|---|---|---|---|
| Radiator | ||||
| Design | Cross-flow | |||
| Coolant filling quantities | ||||
| Manual transmission | ltr. | 7.2 | ||
| Manual transmission with air conditioning | ltr. | 7.2 | ||
| Automatic transmission | ltr. | 7.1 | ||
| Automatic transmission with air conditioning | ltr. | 7.1 |
Cooling System
| Engine | C 20 SEL | |||
|---|---|---|---|---|
| Anti-freeze mixture | ||||
| Water / anti-freeze | ||||
| Manual transmission | ||||
| down to -10 �C | ltr. | 5.7 / 1.5 | ||
| down to -20 �C | ltr. | 4.7 / 2.5 | ||
| down to -30 �C | ltr. | 4.0 / 3.2 | ||
| down to -40 �C | ltr. | 3.4 / 3.8 | ||
| Automatic transmission | ||||
| down to -10 �C | ltr. | 5.6 / 1.4 | ||
| down to -20 �C | ltr. | 4.6 / 1.5 | ||
| down to -30 �C | ltr. | 4.0 / 3.1 | ||
| down to -40 �C | ltr. | 3.4 / 3.7 | ||
| Automatic transmission with air conditioning | ||||
| down to -10 �C | ltr. | 5.6 / 1.4 | ||
| down to -20 �C | ltr. | 4.6 / 1.5 | ||
| down to -30 �C | ltr. | 4.0 / 3.1 | ||
| down to -40 �C | ltr. | 3.4 / 3.7 |
Cooling System
| Engine | C 20 SEL | |||
|---|---|---|---|---|
| Fan | ||||
| Design | Electric fan | |||
| Auxiliary air fan | ||||
| Design | - | |||
| Thermoswitch | ||||
| Installation point | in radiator | |||
| Switching on | �C | 100 | ||
| off | �C | 95 | ||
| Thermostat | ||||
| Design | Bypass | |||
| Start of opening | �C | 92 | ||
| Fully open | �C | 107 | ||
| Compensation tank cap | ||||
| Opening pressure | kPa (bar) | 120 up to 150 (1.2 to 1.5) | ||
| Boiling point | �C | 123 |