Note. Collect drained coolant in a clean container for re-use or disposal.
- Remove thermostat housing. Refer to «Thermostat housing, removing and installing»(ref-276269-S29370771572008010300000) .
Scheme 217
- Remove bolts (arrows) and remove connection -1-.
Scheme 218
- Remove O-ring -3- with thermostat -2- from thermostat housing -1-.
- Heat thermostat in container of water.
| Starts to open | Fully open | Opening travel |
|---|---|---|
| Approx. 80° C | Approx. 105° C 1) | At least 7 mm |
1) Cannot be tested
- Install thermostat housing. Refer to «Thermostat housing, removing and installing»(ref-276269-S29370771572008010300000) .
- Fill cooling system. Refer to «Cooling system, draining and filling»(ref-276269-S04050758062008010300000) .
Tightening torque
| Component | Nm |
|---|---|
| Connection to thermostat housing | 10 |