Motronic M 2.8 F2:TROUBLE CODE TABLE
Trouble
| Code |
Information Sensor
| Cause of Fault | Remedy in |
F0:DATA LIST
| No. | ||
|---|---|---|
| Trouble Code Storage when ... | ||
| Remarks | ||
| 32 | INJECTOR VALVE 6 | |
| VOLTAGE HIGH | 43 | · Short circuit to battery voltage |
Replacement value:
| The defective valve is no longer actuated. |