Caution
Remove mixture regulation oxygen sensor only with engine at operating temperature.
Remove
- 1. Disconnect wiring harness plug for mixture regulating oxygen sensor (2).
- 2. Expose wiring harness for mixture regulating oxygen sensor (3) – note routing.
- 3. Remove mixture regulating oxygen sensor (1) from exhaust manifold. Caution When re-using mixture control oxygen sensor, coat thread of mixture control oxygen sensor with special grease (black).
Install
- 4. Install mixture regulating oxygen sensor into exhaust manifold – Tightening torque 30 Nm / 22 lbf. ft ,
- 5. Connect wiring harness plug for mixture regulation oxygen sensor.
- 6. Route mixture regulating oxygen sensor wiring harness.