Contents Wiring diagrams Section: Power unit All sections

Check: oxygen sensor function Peugeot Partner I

Power unit ~143 words

ECU information available

Actuator test: no OK

Measure parameters: yes

Oxygen sensor test: yes

Characterised by

  • Short circuit to positive
  • Open circuit or short circuit to earth
  • Coherence
  • Not specified

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine running, after an operating time specified in calibrationengine running: - check presence of U = 0.4 to 0.5 V: between terminals 4 and 22 on the control unit engine running, after an operating time specified in calibration (engine overheating): - check presence of U between 0.1 V and 0.9 V: between terminals 4 and 22 on the control unit ignition off, engine ECU: disconnected, oxygen sensor 1350 disconnected: - check continuity of wires A and B

Open circuit or short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
engine running, after an operating time specified in calibrationengine running: - check presence of U = 0.4 to 0.5 V: between terminals 4 and 22 on the control unit engine running, after an operating time specified in calibration (engine overheating): - check presence of U between 0.1 V and 0.9 V: between terminals 4 and 22 on the control unit ignition off, engine ECU: disconnected, oxygen sensor 1350 disconnected: - check continuity of wires A and B

Coherence

conditions under which the fault appearschecks to be made conditions for checking
engine running, after an operating time specified in calibrationengine running: - check presence of U = 0.4 to 0.5 V: between terminals 4 and 22 on the control unit engine running, after an operating time specified in calibration (engine overheating): - check presence of U between 0.1 V and 0.9 V: between terminals 4 and 22 on the control unit ignition off, engine ECU: disconnected, oxygen sensor 1350 disconnected: - check continuity of wires A and B

Not specified

conditions under which the fault appearschecks to be made conditions for checking
engine running, after an operating time specified in calibrationengine running: - check presence of U = 0.4 to 0.5 V: between terminals 4 and 22 on the control unit engine running, after an operating time specified in calibration (engine overheating): - check presence of U between 0.1 V and 0.9 V: between terminals 4 and 22 on the control unit ignition off, engine ECU: disconnected, oxygen sensor 1350 disconnected: - check continuity of wires A and B

Check(s) to be carried out if no fault found

Engine running: check presence of U = 0.4 to 0.5 V: between terminals 4 and 22 on the control unit

Engine running, after an operating time specified in calibration (engine overheating): check presence of U between 0.1 V and 0.9 V: between terminals 4 and 22 on the control unit

Ignition off, engine ECU: disconnected, oxygen sensor 1350 disconnected

  • Check continuity of wires A and B
  • Check: no earth at terminal(s) 4, 22 on the 55V.NR connector