Check: injector 2 - 3 control function Peugeot Partner I

ECU information available

Actuator test: yes

Measure parameters: yes

Characterised by

  • Short circuit to positive
  • Open circuit or short circuit to earth

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition on, engine ECU: disconnected, injectors 1, 2, 3, 4 connected: - no voltage at terminal(s) 1 of the control unit ignition off, engine ECU: disconnected, injector(s) 1, 2, 3, 4 disconnected: - - - check: resistance R of the injectors: R ≃ 16 Ω

Open circuit or short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition off, engine ECU: disconnected, injectors 1, 2, 3, 4 connected: - no earth at terminal(s) 1 on the 55V.NR connector ignition on, engine ECU: connected, injectors 1, 2, 3, 4 connected: - verify: presence of 12 V at terminal(s) 1 on connector 55V.NR (for 5 to 7 seconds) - check: resistance R of the injectors: R ≃ 16 Ω