Home/Peugeot/Partner/Peugeot Partner I (1997-2002)/Repair manual/Power unit/Check: oxygen sensor function — variant 10
Contents Wiring diagrams Section: Power unit All sections

Check: oxygen sensor function — variant 10 Peugeot Partner I

ECU information available

Actuators test: no

Parameter measurements: yes

Characterised by: not specified (short circuit to earth or short circuit to positive or open circuit)

Checks to be carried out if fault is present

Not specified (short circuit to earth or short circuit to positive or open circuit)

conditions under which the fault appearschecks to be made conditions for checking
engine runningcheck: with the engine hot, engine running: - does the voltage U vary between terminals 4 and 22 of connector 55V.NR of the ECU (0,1 V ≤ U ≤ 1 V) ?

Check(s) to be carried out if no fault found

With the engine hot, engine running, check:

- does the voltage U vary between terminals 4 and 22 of connector 55V.NR of the ECU (0.1 V ≤ U ≤ 1 V) ?