Contents Wiring diagrams Section: Power unit All sections

Check: cooling function Peugeot Partner I

ECU information available

Actuator test: yes

Measure parameters: yes

Characterised by

  • Short circuit to positive
  • Short circuit to earth
  • Open circuit

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearsconditions for checking checks to be made
engine runningcontrol unit disconnected, fan 1 and relays 2 disconnected, fan disconnected, ignition on, check: - no voltage at terminal(s) F2 of connector 48V.MR

Short circuit to earth

conditions under which the fault appearsconditions for checking checks to be made
engine runningignition off, control unit disconnected, fan 1 and relays 2 disconnected, fan disconnected, check: - insulation of wire(s) A terminal F2 of connector 48V.MR in relation to the earth

Open circuit

conditions under which the fault appearsconditions for checking checks to be made
engine runningignition off, control unit disconnected, fan 1 and relays 2 disconnected, fan disconnected, check: - continuity and insulation of wire A