Home/Peugeot/Partner/Peugeot Partner I (1997-2002)/Repair manual/Power unit/Check: downstream oxygen sensor heater control function
Contents Wiring diagrams Section: Power unit All sections

Check: downstream oxygen sensor heater control function Peugeot Partner I

ECU information available

Actuator test: no OK

Measure parameters: no OK

Characterised by

  • Short circuit to positive
  • Short circuit to earth
  • Open circuit

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition on; engine ECU, disconnected, downstream oxygen sensor 1351 connected: - check: no voltage on terminal(s) 86 (88V.NR) ignition on; engine ECU, disconnected, downstream oxygen sensor 1350 disconnected: - ignition off: - check the resistance R - downstream oxygen sensor 1351, R between 3 and 5 Ω

Short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition off, engine ECU, disconnected, check: - no earth at terminal(s) 86 on the 88 V.NR connector (1320)

Open circuit

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition on, engine ECU, connected: check: presence of 12 V at terminal 86 on control unit 88V.NR (computer) ignition off: - check the resistance R of the sensor (between terminals 1 and 2), R between 3 and 5 Ω

A 106

B 206

C 306

D 406

E 806

F PARTNER