C-37, Blinkcode Request Circuit
| C-37, Blinkcode Request Circuit |
| Test | Work Order Description | Nominal Value |
| T01 | Check: Short to Voltage of Signal Circuit | |
| Ignition OFF Measure voltage between the following terminals: XD Diagnostic Link X13 Diagnostic Link Terminal 6 & Ground | less than 0.1 V |
| Yes: T02 | No: E03 |
| T02 | Check: Short to Ground/Interruption of Signal Circuit | |
| Ignition ON Measure voltage between the following terminals: XD Diagnostic Link X13 Diagnostic Link Terminal 6 & Ground | greater than 11.5 V |
| Yes: E01 | No: E02 |
| C-37, Blinkcode Request Circuit |
| Result | Cause Of Fault |
| E01 | Defective component: K69 Control Unit - Simtec |
| |
| E02 | Short circuit to ground/interruption of circuit between: XD Diagnostic Link X13 Diagnostic Link Terminal 6 & K69 Control Unit - Simtec Wiring Harness Connector (wiring harness side) Terminal 22 or Defective component: K69 Control Unit - Simtec |
| |
| E03 | Short circuit to voltage between: XD Diagnostic Link X13 Diagnostic Link Terminal 6 & K69 Control Unit - Simtec Wiring Harness Connector (wiring harness side) Terminal 22 or Defective component: K69 Control Unit - Simtec |
| |