C-11, Air Conditioning System Information Switch Circuit
| C-11, Air Conditioning System Information Switch Circuit |
| Test | Work Order Description | Nominal Value |
| T01 | Check: Short to Voltage of Signal Circuit | |
| Ignition OFF Disconnect wiring harness connector from: X7 Instrument Panel & Multec Ignition ON Measure voltage between the following terminals: X7 Instrument Panel & Multec Wiring Harness Connector (wiring harness side) Terminal 21 & Ground Air conditioning system switch OFF | less than 0.2 V |
| Yes: T02 | No: E03 |
| T02 | Check: Short to Ground/Interruption of Signal Circuit | |
| Ignition ON Measure voltage between the following terminals: X7 Instrument Panel & Multec Wiring Harness Connector (wiring harness side) Terminal 21 & Ground Air conditioning system switch ON | greater than 11 V |
| Yes: E01 | No: E02 |
| C-11, Air Conditioning System Information Switch Circuit |
| Result | Cause Of Fault |
| E01 | Short circuit to ground/interruption of circuit between: X7 Instrument Panel & Multec Wiring Harness Connector (control unit side) Terminal 21 & K57 Control Unit - Multec Terminal A8 or Defective component: X7 Instrument Panel & Multec or K57 Control Unit - Multec |
| E02 | Short circuit to ground/interruption of circuit between: S1 Switch - Starter Terminal 15 & X7 Instrument Panel & Multec Terminal 21 or Defective component: S101 Switch - Air Conditioning or S20.1 Switch - Compressor, Low Pressure or S20.2 Switch - Compressor, High Pressure |
| E03 | Short circuit to voltage between: X7 Instrument Panel & Multec Terminal 21 & S101 Switch - Air Conditioning Terminal 5 & K64 Relay - Blower, Air Conditioning, 1.Stage Terminal 2 or Defective component: S101 Switch - Air Conditioning |