Contents Wiring diagrams Section: DOHC Diesel Engine All sections

Cylinder Head Opel Agila A

DOHC Diesel Engine 1 illustration ~101 words

Cylinder Head

  1. 1. Valve guide - external diameter
  2. 2. Cylinder head height
  3. 3. Width of valve seat in cylinder head
  4. 4. Angle of valve seat in cylinder head
  5. 5. Valve stem diameter
  6. 6. Valve seat angle at the valve
  7. 7. Valve length
  8. 8. Valve head diameter
  9. 9. Valve guide, internal diameter
  10. 10. Valve guide - length
  11. 11. Installation height of valve guide
EngineZ 13 DT
Cylinder head height 1)mm105,50 +/- 0,05
Maximum cylinder head deflectionmm0,10
Valve seat angle at valve head45° +/- 20'
Valve guide, outer diameter
Standard dimensionmm11.01 - 11.03
Excess Imm0,05
Excess IImm0,10
Excess IIImm0,25
Valve guide, inner diametermm6.020 – 6.038
Length of the valve guide
Intake valvemm43,50
Exhaust valvemm43,50
Installation height of the valvesmm36.95 - 37.85

Plane Cylinder Head

Installed cylinder head gasketCylinder head heightPlane cylinder headNew cylinder head gasket
Without hole105.4 +/- 0.05 mm0.10 mmOne hole
One hole105.40 +/- 0.05 mm0.10 mmTwo holes
One hole105.30 +/- 0.05 mm0.20 mmTwo holes
Two holesPlaning not possibleReplace cylinder head

Valves

EngineZ 13 DT
Valve length
Intake valvemm107,95
Exhaust valvemm107,95
Permitted impact by valve stemmm0.028 - 0.064
Valve stem diameter
Intake valvemm5.90 – 5.94
Exhaust valvemm5.90 – 5.94
Valve spring
Free length
Intake valvemm37,90
Exhaust valvemm37,90
camshaft
Cam lift
Intake valvemm6,40
Exhaust valvemm7,50
Valve head diameter
Intake valvemm22,00
Exhaust valvemm22,00

Camshaft Housing

EngineZ 13 DT
Diameter, camshaft bearing in camshaft housing
1st bearingmm38.545 – 35.570
2nd bearingmm38.045 – 38.070
3rd bearingmm30.045 – 30.070
Diameter, camshaft bearing journal
1st bearingmm38.500 – 35.515
2nd bearingmm38.000 – 38.015
3rd bearingmm30.000 – 30.015

1