MONTEREY MULTEC M Trouble code Table
Trouble
| code | Information sensor |
|---|---|
| Cause of Fault | Directions for Remedy in |
FO:DATA LIST
| No. | Trouble code storage when ... | Remarks |
|---|---|---|
| 21 | THROTTLE POSIT. | |
| SENSOR CIRCUIT | 05, 06 | · Intake manifold absolute pressure less than 500 hPa |
Engine running at partial load, at operating temperature
· Engine speed less than 1200 rpm
· The following trouble codes are not stored: 33
· Throttle position sensor voltage greater than 4.6 V
· The above conditions must apply for at least 5 sec.
If trouble code 21 has been detected, the control module expects a substitute BLM cell, depending on the engine speed and the throttle position.
| 21 | THROTTLE POSIT. | |
|---|---|---|
| SENSOR CIRCUIT | 05, 06 | · Engine running |
· Throttle position sensor voltage less than 0.2 V
If trouble code 21 has been detected, the control module expects a substitute BLM cell, depending on the engine speed and the throttle position.