GMP4 6VD1 F0:DATA LIST
| No. | Tech 1 Display | Conditions for checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 06 | BAROMETER SENSOR | Ignition ON |
Note:
The parameter BAROMETER SENSOR takes value of MAP SENSOR when ignition is turned off.
or
Throttle valve opening is greater than 38 % and
| Engine running in engine speed range from 2000 to 4500 rpm | 0.9... 1.1 bar |
4.26... 5.0 V
| (depending on altitude) | - | A1, D9, A11 |