Remove
- 1. Remove air cleaner housing with air intake hose and hot film mass air flow meter – see operation "Air Cleaner Housing, Remove and Install".
- 2. Push top injection pipe insulation to side in direction of arrow - ensure that insulation is not damaged!
- 3. Remove wiring harness plug (1).
- 4. Remove fuel temperature sensor (2).
Install
- 5. Install new fuel temperature sensor in injection pump.
- 6. Attach wiring harness plug to fuel temperature sensor.
- 7. Fit top injection pump insulation - ensure that it is seated correctly!
- 8. Install air cleaner housing with air intake hose and hot film mass air flow meter – see operation "Air Cleaner Housing, Remove and Install".