Mass Air Flow (MAF) Sensor Assembly Install
Remove
- Disconnect the negative battery cable.
- Loosen the clamp and pull the flexible air intake duct away from the mass air flow (MAF) sensor assembly.
- Disconnect the MAF sensor connector.
- Remove the screw, two places, attaching the MAF sensor assembly (2) to the upper air cleaner housing (3).
- Remove the MAF sensor assembly.
Install
Note: Ensure that the arrow on the MAF sensor housing face toward the air flow direction.
- Install the MAF sensor assembly to the air cleaner upper housing.
Tighten
Tighten the mass air flow sensor assembly attaching screws to 2 N•m (18 lb-in).
- Connect the flexible air intake duct and tighten the clamp.