Sensors
- Type: Hall effect sensor
- Specifications
| Operation condition (°C)°F | ((-)40 ~ 150)) -40 ~ 302 |
| Air gap(mm)in. | (1.2 ~ 1.8) 0.0472 ~ 0.0709 |
| Output voltage(V) | High | 1.18 ~ 1.68 |
| Low | 0.59 ~ 0.84 |
- Type: Hall effect sensor
- Specifications
| Operation condition (°C)°F | ((-)40 ~ 150)) -40 ~ 302 |
| Air gap(mm)in. | (0.85 ~ 1.3) 0.0335 ~ 0.0512 |
| Output voltage | High | 1.18 ~ 1.68 |
| Low | 0.59 ~ 0.84 |
Oil Temperature Sensor
- Type: Negative thermal coefficient type
- Specifications
| Temp.[(°C)°F] | Resistance (kohms) |
| (-40)-40 | 48.1 |
| (-20)-4.0 | 15.6 |
| (0)32.0 | 5.88 |
| (20)68.0 | 2.51 |
| (40)104.0 | 1.11 |
| (60)140.0 | 0.61 |
| (80)176.0 | 0.32 |
| (100)212.0 | 0.18 |
| (120)248.0 | 0.10 |
| (140)284.0 | 0.06 |
| (150)302.0 | 0.05 |
Inhibitor Switch
- Type: Combination of output signals from 4 terminals
- Specifications
| Power supply (V) | 12 |
| Output type | Combination of output signals |
Solenoid Valves
Direct control VFS[26/B, T/CON]
- Control type: Normal low type
| Control Pressure kpa (kgf/cm 2 , psi) | 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54) |
| Current value(mA) | 50 ~ 850 |
| Internal resistance(ohms) | 5.1 |
Direct control VFS[UD/B, OD/C, 35R/C]
- Control Type: Normal high type
| Control Pressure kpa (kgf/cm 2 , psi) | 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42) |
| Current value(mA) | 50 ~ 850 |
| Internal resistance(ohms) | 5.1 |
Line Pressure Control VFS
- Control type: Normal high type
| Control Pressure kpa (kgf/cm 2 , psi) | 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42) |
| Current value(mA) | 50 ~ 850 |
| Internal resistance(ohms) | 5.1 |
ON/OFF Solenoid Valve(SS-A, SS-B)
- Control type: Normal low type
| Control pressure kpa (kgf/cm 2 , psi) | 490.33(5.0, 71.12) |
| Internal resistance(ohms) | 10 ~ 11 |
| SS-A | SS-B | UD/B-VFS | OD/C-VFS | 35R/C-VFS | 26/B-VFS |
| N/H | N/H | N/H | N/L |
| N, P | | | | | | |
| 1 | | | | | | |
| 2 | | | | | | |
| 3 | | | | | | |
| 4 | | | | | | |
| 5 | | | | | | |
| 6 | | | | | | |
| L | | | | | | |
| R | | | | | | |
| Connected status : Connected at vehicle speed above 8km/h |
SOLENOID VALVE OPERATION TABLE
Lubricants
| Item | Specified lubricant | Quantity |
| Transaxle fluid | SK ATF SP-IV, MICHANG ATF SP-IV, NOCA ATF SP-IV, Kia Genuine ATF SP-IV or other brands meeting the above specification approved by Kia Motors Corp. | 7.3L (1.93 U.S gal., 7.71 U.S.qt., 6.42 lmp.qt.) |
Sealant
| Item | Specified sealant |
| Rear cover | LOCTITE FMD-546(P/N: UM010CH046) or equivalent or THREE-BOND TB1281B |
| Torque converter housing |
Special Service Tools
Tools (Number and name) Illustration Use 09200-38001 Engine support fixture (Beam) Removal and installation of the transaxle. Except lower supporter, use beam only with new engine support fixture supporter(SST No.:09200-2S000) 09200-2S000 Engine support fixture (supporter) Removal and installation of the transaxle. [Using with handle (SST No.:09200-38001)] 09200-4X000 Engine support fixture (adapter) Removal and installation of the transaxle. [Using with handle (SST No.:09200-38001) and supporter(SST No.: 09200-2S000)] 09452-26100 Oil seal installer Installation of transaxle case oil seal. [Using with handle (SST No.:09231-H1100)] 09231-H1100 Bar Installation of transaxle case oil seal. [Using with oil seal installer (SST No.:09452-26100)]