Consumables (dow automotive)
| tool | reference | designation |
|---|---|---|
| [9799 L8] | single-pot quick setting kit | |
| "a" adhesive cartridge "b" sachet of glass cleaner "c" instructions "d" un-cut nozzle "e" pre-cut nozzle "f" Primer applicator tube | ||
| [9799 L7] | two-pot ultra-quick setting kit | |
| "a" cartridge of two-pot adhesive "b" sachet of glass cleaner "c" instructions "d" un-cut nozzle "e" pre-cut nozzle "f" Primer applicator tube | ||
| [9799 L9] | standard kit | |
| "a" adhesive cartridge "b" sachet of glass cleaner "c" instructions "d" un-cut nozzle "e" pre-cut nozzle "f" Primer applicator tube | ||
| [9799 N0] | extra cartridge in the kit [9799 L8] | |
| adhesive cartridge |
Tooling
Pneumatic gun with air flow adjustment
Data
| reference | designation | time of immobilisation of the vehicle after bonding |
|---|---|---|
| [9799 L8] | single-pot quick setting kit | 1 hr |
| [9799 L7] | two-pot ultra-quick setting kit | 1 hr |
| [9799 L9] | standard kit | 2 hr |
| [9799 N0] | extra cartridge in the kit [9799 L8] | 1 hr |
Compatibility
- All bonding of original polyurethane used in bonding of window glass
- Glass with integral radio aerial (non-conductive product)
Optimum temperatures for using the product: between 10°C and 35°C
NoteThe maximum time for bonding the glass is the time between extruding of the product and positioning of the glass to be bonded. the maximum time for bonding the glass varies as a function of the temperature and moisture level (22°C and 50% humidity)
Drying in air at ambient temperature
NoteImmobilisation time for the vehicle after bonding is approx. 1 h
Consumables (henkel)
| tool | reference | designation |
|---|---|---|
| [9799 H8] | ultra rapid kit | |
| "a" adhesive cartridge "b" instructions "c" adjustable nozzle "d" un-cut nozzle "e" applicator "f" primer "g" window glass cleaning kit | ||
| [9799 H9] | fast kit | |
| "a" adhesive cartridge "b" instructions "c" adjustable nozzle "d" un-cut nozzle "e" applicator "f" primer "g" window glass cleaning kit | ||
| [9799 J7] | standard kit | |
| "a" adhesive cartridge "b" instructions "c" pre-cut nozzle "d" un-cut nozzle "e" applicator "f" primer "g" window glass cleaning kit | ||
| [9799 J0] | extra ultra-quick cartridge | |
| adhesive cartridge | ||
| [9799 J1] | extra ultra-quick cartridge | |
| adhesive cartridge | ||
| [972676] | extra standard cartridge | |
| adhesive cartridge |
Tooling
Pneumatic gun with air flow adjustment
Data
| reference | designation | time of immobilisation of the vehicle after bonding |
|---|---|---|
| [9799 H8] | ultra rapid kit | 15 minutes (with cartridge heated) |
| [9799 H9] | fast kit | 2 hr |
| [9799 J7] | standard kit | 6 hr |
| [9799 J0] | extra ultra-quick cartridge | 15 minutes (with cartridge heated) |
| [9799 J1] | extra ultra-quick cartridge | 2 hr |
| [9726 76] | extra standard cartridge | 6 hr |
Compatibility
- All bonding of original polyurethane used in bonding of window glass
- Glass with integral radio aerial (non-conductive product)
Optimum temperature for using the product: between 10°C and 35°C
NoteThe maximum time for bonding the glass is the time between extruding of the product and positioning of the glass. the maximum time for bonding the glass varies as a function of the temperature and moisture level (22°C and 50% humidity)
Drying in air at ambient temperature
NoteImmobilisation time for the vehicle after bonding is approx. 1 h
Data on hygiene and safety
The data files on health and safety can be consulted on the internet site http://quickfds.com
NoteUse the Parts No. for searches of the hygiene and safety data
Bonding method
Preparation of the bonding surfaces
Clean the bonding surfaces of the glass, as well as the edges; using the cleaning cloth
Wipe with the dry cloth or use a clean rag
Note on use of bonding primer
Leave the primer to dry for 5 minutes
WarningNever carry out bonding without using bonding primers
WarningIf there is a metal support, this support should be covered with a paint layer (top lacquer or cataphoresis coating)
WarningIf there are supports made from synthetic materials (polyester, PVC, PU, RIM) the lacquer primer can be applied directly on the unpainted material
WarningIn the case of a new replacement body, do not damage the anti-corrosion protection (cataphoresis)
WarningIn the case of a component replacement (e.g. windscreen pillar), do not remove the anti-corrosion protection (cataphoresis) on the bonding zone
WarningOn bare panel, apply the bonding primer in two layers, with a drying time of 5 to 10 minutes bewteen the two layers
WarningPrime the bonding zone before painting
WarningNever paint the bonding zone
Bonding
WarningApply the adhesive strip on the entire periphery of the glass in one uninterrupted action
Fit the glass on the bodywork