Contents Wiring diagrams Section: Exhaust All sections

Function Test Audi TT 8N

Exhaust ~136 words

Note. If the accelerator pedal is depressed during the test, the test will be aborted.

  1. Connect the scan tool.
  2. Start the engine and run at idle for at least 15 minutes.
  3. Select "Mode 8: Tank Leak Test".
  4. Select " Tank Leak Test".
  1. Check the specified value of the tank leak test at idle.
  2. The following may be displayed on the scan tool screen
Tank leak testSpecified value
Test function active Test function is being initiated, please wait Test off Test abortedTest OK
  1. Switch the ignition off.

If the specified result is obtained

System OK.

If the specified result is not obtained

  1. Repeat the tank leak test, switch the ignition off and start the engine again and let run for 15 minutes at idle.
  2. Switch the ignition off.

If the specified result is again not obtained

  1. A leak may be present. Refer to --> «Evaporative Emission (EVAP) System, Leak Checking»(ref-276276-S04414908562008010300000) .

End of diagnosis.