Air Flow Guide
The air guidance system (air flow guide) was re�designed because of the installation position of the engine.
In contrast to the Omega B, the intake plenum was rotated through 180�.
| 1 | Intake plenum with |
|---|---|
| � | Intake plenum switchover valve |
| � | Solenoid valve for intake plenum switchover valve |
| � | Vacuum unit for intake plenum switchover valve |
| 2 | Expansion chamber |
| 3 | Resonance pipes with |
| � | Resonance pipe switchover valve |
| � | Solenoid valve for resonance pipe switchover valve |
| � | Vacuum unit for resonance pipe switchover valve |
| 4 | Upper part of air cleaner housing |
| 5 | Air intake supports |
| 6 | Lower part of air cleaner housing |
| 7 | Air cleaner |
| 8 | Air cleaner cover |
| 9 | Hot film mass air flow meter |
| 10 | Air intake hose with |
| � | Intake air temperature sensor |