Z 16 Se
Remove
- 1. Unlatch and disconnect exhaust gas recirculation valve wiring harness plug (2)
- 2. Remove fastening bolts for exhaust gas recirculation valve (1) and remove exhaust gas recirculation valve
Install
- 3. Clean sealing surfaces and remove gasket remnants
- 4. Attach exhaust gas recirculation valve with new gasket to intake manifold – tightening torque 20 Nm
- 5. Attach wiring harness plug for exhaust gas recirculation valve