DTC SUMMARY
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
| P2420 | Evaporative Emission Pressure Switching Valve Stuck OFF | Following condition met during key-off EVAP monitor: EVAP pressure change when vent valve closed (on) less than 0.3 kPa(gauge) [2.25 mmHg(gauge)] | Canister pump module (reference orifice, leak detection pump, vent valve) Connector/wire harness (Canister pump module - ECM) Canister (filter inside canister clogged) ECM | Comes on | DTC stored | DTC for Mexico Models - Not apply |
| DTC No. | Monitoring Item | Detection Timing | Detection Logic |
| P2420 | Vent valve stuck open (vent) | While ignition switch off | 2 trip |
The vent valve is built into the canister pump module.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
| P2610 | ECM / PCM Internal Engine Off Timer Performance | ECM internal malfunction. | ECM | Comes on | DTC stored | DTC for Mexico Models - Not apply |
| DTC No. | Monitoring Item | Detection Timing | Detection Logic |
| P2610 | Soak timer (built into ECM) | Ignition switch off | 2 trip |