Home/Honda/Insight/Honda Insight ZE2 рестайлинг (2011-2014)/Repair manual/Testing & Diagnostics/DTC P2610: PCM Ignition Off Internal Timer Performance Malf…
Contents Section: Testing & Diagnostics All sections

DTC P2610: PCM Ignition Off Internal Timer Performance Malfunction Honda Insight ZE2 рестайлинг

Note. Before you troubleshoot, record all freeze data and any on-board snapshot, and review the general troubleshooting information (see GENERAL TROUBLESHOOTING INFORMATION ).

  1. Turn the ignition switch to ON (II).
  2. Clear the DTC with the HDS.
  3. Check for Pending or Confirmed DTCs with the HDS. Is DTC P2610 indicated? YES -Go to step 4. NO -Intermittent failure, the system is OK at this time.
  4. Update the PCM if it does not have the latest software (see «PCM UPDATE»(ref-513153-S08553155092012110700000) ), or substitute a known-good PCM (see «SUBSTITUTING THE PCM»(ref-513169-S18138486322012110700000) ).
  5. Check for Pending or Confirmed DTCs with the HDS. Is DTC P2610 indicated? YES -If the PCM was updated, substitute a known-good PCM (see «SUBSTITUTING THE PCM»(ref-513169-S18138486322012110700000) ), then recheck. If the PCM was substituted, go to step 1 . NO -If the PCM was updated, troubleshooting is complete. If the PCM was substituted, replace the original PCM (see «PCM REPLACEMENT»(ref-513153-S08243124262012110700000) ). If any other Pending or Confirmed DTCs are indicated, go to the indicated «DTC'S TROUBLESHOOTING»(ref-513153-S06499438282012110700000) .