1. Disconnect wiring harness from charge pressure sensor
- Release integral clip
2. Remove preheating control unit (1)
- Remove nut
3. Disconnect wiring harness connector from preheating control unit
- Release integral clip
4. Connect wiring harness connector to preheating control unit
- Secure integral clip
5. Install preheating control unit (1)
6. Connect wiring harness connector to charge pressure sensor
- Secure integral clip