Contents Section: Air Conditioning All sections

Test Step 18 Opel Tigra A

Air Conditioning ~159 words
TestTesterCheckNotesNominal
StepMultimeter MKM-587-AofbetweenValue
18Voltmeter range 20 V, DCVoltage supply, AC fan motor switch S24 andWiring harness plug
· Disconnect wiring harness plug from AC fan motor M10
function ofM10 (1)Ground· Ignition ON» 11.5 V
switch positionsM10 (2)Ground· Switch S24 to switch» 11.5 V
1 - 4M10 (4)
Groundpositions 1-4
» 11.5 V
Relay K7 Ter.  86 (2)
Ground· Disconnect relay K7 *)» 11.5 V
Possible cause of fault, trouble-shooting

1. MAXI fuse F15/30A defective.

2. AC relay K6 defective - see test step 07.

3. Lead interruption between AC relay K6/Ter. 87 (8) and AC fan motor switch S24/Ter. G+ (7).

4. AC fan motor switch S24 defective.

5. Lead interruption between output MAXI fuse F15/30A and AC relay K6/Ter. 30 (4)

6. Lead interruption between AC fan motor switch S24/Ter. 1 (6) and wiring harness plug for AC fan motor M10 (1).

7. Lead interruption between AC fan motor switch S24/Ter. 2 (5) and wiring harness plug for AC fan motor M10 (2).

8. Lead interruption between AC fan motor switch S24/Ter. 3 (4) and wiring harness plug for AC fan motor M10 (4).

9. Lead interruption between AC fan motor switch S24/Ter. 4 (3) and AC fan relay, 4th speed, K7/Ter. 86 (2).

*) For this, remove glove compartment and detach relay frame beside glove compartment

( ) Terminal in wiring harness plug