TestTesterCheckNotesNominal
StepMultimeter MKM-587-AofbetweenValue
13Voltmeter rangeVoltage supply,K52/Ter. 86 (4)Ground· Disconnect relay K52
· Ignition ON» 11.5 V
20 V, DCradiator fan relay K52
K52/Ter. 30 (2)Ground· Switch S101 ON» 11.5 V
Ohmmeter rangeK52/Ter. 87 (8)Ground· Ignition OFF
· Disconnect relay K52» 0 W
200 WK52/Ter. 85 (6)Ground· Disconnect wiring harness plug from switch S20

· Bridge contacts 3 and 4 in wiring harness plug S20

» 0 W
Voltmeter range 20 V, DCK52/Ter. 87A (5)Ground· Disconnect relay K52

· Disconnect wiring harness plug from switch S128*)

· Bridge contacts 2 and 3 of wiring harness plug for switch S128

· Ignition ON

· Important: radiator fan motor M4 starts running

» 11.5 V
Possible cause of fault, trouble-shooting

1. Fuse F17/10A defective.

2. Fuse F20/30A defective.

3. Lead interruption between radiator fan relay K52/Ter. 86 (4) and X6 (61/pin).

4. Lead interruption between X6 (61/bushing) and fuse F17/10A.

5. Lead interruption between radiator fan relay K52/Ter. 30 (2) and radiator fan relay K51/Ter. 87 (8).

6. Lead interruption between radiator fan relay K52/Ter. 30 (2) and X44 (1/pin).

7. Lead interruption between X44 (1/bushing) and radiator fan relay and AC fan motor, 1st speed, K26/Ter. B (5).

8. Lead interruption between radiator fan relay K51/Ter. 30 (4) and auxiliary fan motor M11 (BRWS/brown-white).

9. Lead interruption between X44 (2/pin) and auxiliary fan motor M11 (BRWS/brown-white).

10. Lead interruption between radiator fan relay K52/Ter. 87 (8) and grounding point 2.

11. Lead interruption between radiator fan relay K52/Ter. 87A (5) and radiator fan motor M4 (RTWS/red-white).

12. Radiator fan motor M4 defective - see test step 01.

13. Lead interruption between radiator fan motor M4 (BR/brown) and grounding point 2.

14. Lead interruption between radiator fan relay K52/Ter. 85 (6) and coolant temperature switch S128 (2).

15. Lead interruption between radiator fan relay K52/Ter. 85 (6) and pressure switch ASSY. S20 (4).

16. Pressure switch ASSY. S20 defective - see test step 06.

17. Lead interruption between pressure switch ASSY. S20 (3) and grounding point 2.

18. Coolant temperature switch S128 defective - see test step 15.

19. Lead interruption between coolant temperature switch S128 (3) and grounding point 2.

*) For this, remove front panelling

( ) Terminal in wiring harness plug