| Test | Tester | Check | Notes | Nominal | |
|---|---|---|---|---|---|
| Step | Multimeter MKM-587-A | of | between | Value | |
| 08 | Voltmeter range 20 V, DC | Voltage supply, AC switch S101 and lead to X6 | |||
| X6 (57/bushing) | Ground | · Separate plug connection X6 *) |
· Ignition ON
· Switch S101 ON
| » 11.5 V |
|---|
| Possible cause of fault, trouble-shooting |
1. AC relay K6 defective - see test step 07.
2. Lead interruption between AC relay K6/Ter. 87 (8) and AC switch S101/Ter. (C)
3. Lead interruption between AC switch S101 (A) and X6 (57/bushing).
4. AC switch S101 defective. (AC switch S101 is not defective if the telltale in the switch illuminates after actuation of the switch).
*) For this, remove inner panelling from lower left A pillar.
( ) Terminal in wiring harness plug