Test Step 09 Opel Tigra A

Air Conditioning ~121 words
TestTesterCheckNotesNominal
StepMultimeter MKM-587-AofbetweenValue
09Voltmeter rangeVoltage supply,K7/Ter. 86 (2)Ground· Ignition ON
· Switch S24 in position 4» 11.5 V
20 V, DCAC fan motor relay, 4thK7/Ter. 30 (4)Ground· Relay K7 installed» 11.5 V
speed, K7*
K7/Ter. 87 (8)Ground» 11.5 V
K7/Ter. 87 (8)Ground· Ignition ON

· Switch S24 in position 3

· Relay K7 installed

» 7 V
Ohmmeter range 200 W
K7/Ter. 85 (6)Ground· Ignition OFF
· Relay K7 removed» 0 W
Possible cause of fault, trouble-shooting

1. Lead interruption between AC fan motor relay, 4th speed, K7/Ter. 30 (4) and AC relay K6/Ter. 87 (8).

2. Lead interruption between AC fan motor relay, 4th speed, K7/Ter. 86 (2) and AC fan motor switch S24/Ter. 4 (3).

3. Lead interruption between AC fan motor relay, 4th speed, K7/Ter. 85 (6) and grounding point 2.

4. AC fan motor switch S24 defective - see test step 18.

5. Lead interruption between AC fan motor M10 (3) and AC fan motor relay, 4th speed, K7/Ter. 87 (8).

*) For this, remove glove compartment and detach relay frame beside glove compartment.

( ) Terminal in wiring harness plug