Contents Section: Board Computer All sections

Variations Opel Senator B

Board Computer ~223 words

Variations

· Board Computer Checkable Using TECH 1

As of Model Year 1989, board computers with serial interface are used.

These board computers can be checked using TECH 1 (section 5.4) or Diagnostic Switch KM-640 (section 5.6).

Board Computer with Serial Interface

ProductionService Department
Display PrintColour
Ident. No.Alpha CodeParts No.Catalogue No.
Germanblack90 314 457EH90 349 01312 36 049
blue90 326 941HA90 350 05912 36 064
beige90 326 942HC90 350 06012 36 063
grey90 326 943HE90 350 06112 36 062
Englishblack90 314 458EL90 349 01412 36 050
blue90 326 944HF90 350 06212 36 061
beige90 326 945FA90 350 06312 36 060
grey90 326 946FC90 350 06412 36 059
Frenchblack90 314 459EU90 349 01512 36 051
blue90 326 947FE90 350 06512 36 058
beige90 326 948FF90 350 06612 36 057
grey90 326 949FH90 350 06712 36 056
Italian/Spanishblack90 314 460EP90 349 01612 36 052
blue90 326 950FL90 350 06812 36 055
beige90 326 951FP90 350 06912 36 054
grey90 326 952FU90 350 07012 36 053

· Board Computer Not Checkable Using TECH 1

Board computers without serial interface (Model Years 1987 and 1988) cannot be checked using TECH 1.

To check these board computers, see Checking Procedures "BOARD COMPUTER OMEGA/CARLTON/SENATOR-B".

Board Computers without Serial Interface

ProductionService Department 1)
Display Print
Ident. No.Alpha CodeParts No.Catalogue
German90 253 987CN90 273 36412 36 037
English90 253 988CP90 273 36512 36 038
French90 303 450CR90 272 75012 36 042
Italian/Spanish90 303 449CQ90 272 74912 36 041

1) Used up board computers without serial interface are replaced in the Service Department by board computers with serial interface. These board computers cannot be tested using TECH 1, however, since the serial interface of the board computer has no connection to the diagnostic plug.

A check of the board computer is only possible using diagnostic switches (see section 5.6 ).

Recognition without Removal

Whether or not the board computer has a serial interface can also be determined without removal. For this, the board computer is put into the mode: Output Program Memory Code, Alpha Code (see section 5.6.1).

With board computers without serial interface, the time display continues to indicate the time (see illus. C 4372).

Fehler! Datei kann nicht geöffnet werden!
.P. C4372.tif97,5tiff;;

With board computers with serial interface, the alpha code and the version number are displayed in the time display (see illus. D 1390).

After releasing both keys, the display "Impulse/km" appears in place of the alpha code with the version number.Fehler! Datei kann nicht geöffnet werden!
.P. D1390.tif97,5tiff;;