Contents Section: Board Computer All sections

Diagnostic Mode d:1 Opel Senator B

Diagnostic Mode d:1

Select diagnostic mode 1 in order to read out stored trouble code.

The clock display shows designation "d : 1".

The function display introduces the trouble code read-out by flashing the number "12" three times and then flashing the trouble codes three times in numerical order.

The entire trouble code set is repeatedly given until diagnostic mode 1 is exited.

Fehler! Datei kann nicht geöffnet werden!
.P. C4365.tif97,5tiff;;

If no fault is present, "----" is flashed instead of the trouble code.

After removal of cause of fault, the fault memory can be erased by actuating the start key.

Fehler! Datei kann nicht geöffnet werden!
.P. C4363.tif97,5tiff;;
TroubleTrouble Code ExplanationTrouble-shooting
Code
167The trouble code is set when the- Tank indicator in instrument does not function:
the fuel gauge signal voltage at1. Fuel gauge or connection defective (short circuit to ground)
the board computer is too small.2. Instrument defective
Simultaneously, the range function
is blocked by a flashing "F".-Tank indicator in instrument functions:
1. Lead interruption between fuel gauge and board computer Ter. 26,
bimetal measuring device or Ter. 8, on VECTRA/CAVALIER with
LCD instrument
2. Wrong program memory installed
3. Board computer defective
168The trouble code is set when the- Tank indicator in instrument does not function:
the fuel gauge signal voltage at1. Fuel gauge or connection defective (interruption)
the board computer is too large.2. Ground connection at fuel gauge defective
Simultaneously, the range function3. Instrument defective
is blocked by a flashing "F".
- Tank indicator in instrument functions:
1. Wrong program memory installed
2. Board computer defective
169The trouble code is set when the1. Disconnect temperature sensor plug connection P13 and measure
temperature sensor signal voltage atresistance of temperature sensor (multimeter, measuring range: 2
the board computer is too low.Nominal value: 700 W - 135 kW.
Simultaneously, the outside2. Short circuit to ground of lead between board computer Ter. 13 and
temperature function is blocked by atemperature sensor plug P13
flashing "F".3. Board computer defective
171The trouble code is set when the1.Disconnect temperature sensor plug connection P13 and measure
temperature sensor signal voltage atresistance of temperature sensor (multimeter, measuring range: 2
the board computer is too high.Nominal value: 700 W - 135 kW.
Simultaneously, the outside2.Lead interruption between board computer Ter. 13 and temperature
temperature function is blocked by asensor plug P13
flashing "F".3.Lead interruption between board computer Ter. 12 and temperature
sensor plug P13
4.Board computer defective
173The trouble code is set when the1.Short circuit to ground of lead between board computer Ter. 24 and
injection control unit signal showscontrol unit of injection system
a ground level longer than 500 ms;2.Board computer defective
The following functions are blocked3.Control unit of injection system defective
by a flashing "F".
- current consumption
- average consumption
- range