Multi Info Display MID F2: TROUBLE CODE TABLE
| Trouble Code | Information Sensor |
|---|---|
| Cause of Fault | Remedy in |
F0: DATA LIST
| No. | Trouble Code Storage when... |
52
| RE - PROGRAM |
PROGRAM MEMORY
| - |
|---|
| · The EEPROM content does not have the correct value (EEPROM not programmed) |
· The trouble code is set without delay
Effects:
· The first MID display shows "program" and the second shows the alpha code
· The "current consumption", "average consumption", "average speed", "range" and ambient temperature display functions are blocked.
· The "Check Control" function of the MID is switched off
Note:
The fault memory is automatically deleted after successful programming