Contents Wiring diagrams Section: Automatic HVAC System All sections

Climate System: Specifications Saab 9-5 II

Fastener Tightening Specifications

ApplicationSpecification
MetricEnglish
Air Inlet Housing Bolt2, 5 Nm23 lb in
Compressor and Condenser Hose Assembly Bolt22 Nm16 lb ft
Compressor and Condenser Hose Fastener (A20 NHT/LDK) (LAU/28NER)20 Nm15 lb ft
Compressor and Condenser Hose Fastener (LBS/A20DTH)22 Nm16 lb ft
Compressor Bracket Fastener (LDK/A20 NHT)22 Nm16 lb ft
Compressor Bracket Fastener (LAU/A28NER)42 Nm31 lb ft
Compressor Fastener22 Nm16 lb ft
Compressor Hose Fastener20 Nm15 lb ft
Compressor Pressure Relief Valve10 Nm89 lb in
Compressor Tube Assembly Nut22 Nm16 lb ft
Condenser Hose Fasteners20 Nm15 lb ft
Engine Coolant Exhaust Muffler Bracket Fastener9 Nm80 lb in
Engine Coolant Heater Air Supply Hose Retainer3, 5 Nm31 lb in
Evaporator Hose Fastener20 Nm15 lb ft
Evaporator Hose Stud Bolt15 Nm11 lb ft
Evaporator Thermal Expansion Valve Fastener7 Nm62 lb in
Liquid Line to Condenser Fasteners22 Nm16 lb ft
Power Steering Fluid Cooling Pipe Bracket Fastener9 Nm80 lb in
Refrigerant Pressure Sensor7, 4 Nm66.4 lb in

Refrigerant System Specifications

ApplicationSpecification
MetricEnglish
Abrupt refrigerant loss60 ml (1)2.0 oz (1)
When charging system after recovery20 ml0.7 oz
Compressor Replacement The service compressor is shipped with a specified amount of PAG oil. NOTE: Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.
Compressor oil (Sanden PXE16)110 ml3.7 oz
Compressor Oil (Delphi SP17)150 ml5.0 oz
Condenser Replacement30 ml (2)1.0 oz (2)
Evaporator Replacement40 ml (2)1.3 oz (2)
Any Line Set (Hose/Tube or Tube Assembly) Replacement20 ml (2)0.7 oz (2)
Total System PAG Oil Capacity - Sanden110.0 ml3.7 oz
Total System PAG Oil Capacity - Delphi150 ml5.0 oz
R-134a
Refrigerant Charge (R-134a)0.60 kg1.5 lb
(1) Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. (2) If more than the specified amount of PAG oil was drained from a component, add the amount drained.
NOTE
Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.
(1)Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component.
(2)If more than the specified amount of PAG oil was drained from a component, add the amount drained.