Home/Peugeot/405/Peugeot 405 I (1987-2014)/Repair manual/Power unit/Check: torque reduction function — variant 2
Contents Wiring diagrams Section: Power unit All sections

Check: torque reduction function — variant 2 Peugeot 405 I

ECU information available

Actuators test: no

Parameter measurements: yes

Checks to be carried out if fault is present

conditions under which the fault appearschecks to be made conditions for checking
engine running, vehicle moving, open circuit: short circuit to positive or short circuit to earth on terminal(s) 31 (control unit)check: - engine running, with P or N engaged - presence of 12 V at terminal 31 on control unit - engine running, in engaged gear - R - D - 3 - 2 engine XU - R - D - 2 - 1 engine TU - presence of 0 V at terminal 31 on control unit

Check(s) to be carried out if no fault found

Check:

- engine running, with P or N engaged

- presence of 12 V at terminal 31 on control unit

Engine running, in engaged gear

  • R - D - 3 - 2 (engine XU)
  • R - D - 2 - 1 (engine TU)

Presence of 0 V at terminal 31 on control unit