Home/Peugeot/405/Peugeot 405 I (1987-2014)/Repair manual/Power unit/Check: downstream oxygen sensor function (ageing)
Contents Wiring diagrams Section: Power unit All sections

Check: downstream oxygen sensor function (ageing) Peugeot 405 I

ECU information available

Actuator test: no OK

Measure parameters: yes

Oxygen sensor test: yes

Characterised by: oscillation ageing

Checks to be carried out if fault is present

Oscillation ageing

conditions under which the fault appearschecks to be made conditions for checking
engine running, for 10 - 15 minute(s) vehicle driving at different engine speeds, steady speeds total time of at least 1 minute(s) in gear no. 4 at 50 km/h total time of at least 2 minute(s) in gear no. 5 at 70 km/hverify: air leak on the exhaust verify (engine hot at idle): U = 0,6 - 0,7 V between terminals 71 and 70 on the control unit replace the upstream oxygen sensor road test the vehicle to try to reproduce the fault if incorrect: replace the downstream oxygen sensor