Contents Wiring diagrams Section: Power unit All sections

Application: tools Peugeot 405 I

Power unit ~317 words

Autodiagnostic tester (TAD4.99)

Enables

  • Reading the fault codes
  • Erasing the fault codes
  • The actuator test

Connection to the test connector C1300 - position 1 (coloured green).

Peugeot on-board fault recorder (TEP 92)

Enables

  • Fault reading
  • The actuator test
  • Road testing
  • Parameter measurements
  • Erasing the faults

Connection to the test connector C1300 (coloured green).

SOURIAU 2690 / SAGEM SAR 860 diagnostic equipment

Enables

  • The wiring tests
  • The starting test
  • Parameter measurements
  • Reading the fault codes
  • Erasing the fault codes
  • The actuator test

Connections: see instructions for use

Peugeot electrical break-out box (B.I.P. 722)

Enables

  • Measurements on electrical circuits
  • Simulation of component operation

Connection to the control unit 1320

  • Connect the adapter (1) to the extension lead (55)
  • Disconnect the control unit 1320
  • Connect the vehicle harness to the blue adaptor [1]

Depending on the checks to be made, it may be necessary to connect the adaptor to the control unit

Connection to the double relay 1304

  • Connect the 2 x 15-way black and white adaptor (3) to the extension lead
  • Connect the mauve adapters (4) to both ends of the black adaptor
  • Disconnect the double relay and connect it to the black adaptor
  • Connect the vehicle harness to the black adaptor

In relation to the checks to be carried out, it may be necessary to disconnect the double relay from the black adaptor

Coded anti-start

Connection to the keypad

  • Connect the adapter [OR] to the extension lead ((2))
  • Disconnect the keypad 8200 and connect it to the NR connector (15-way) connected to the OR adaptor
  • Connect the vehicle harness to the adaptor OR

Tools to be produced locally

Two flying leads (5) 20 cm long fitted with a 5A fuse and 6,35 mm male terminals to short circuit the connector terminals

A flying lead (6) 20 cm long fitted with a 5A fuse and 2,8 mm male terminals to shunt the terminals of the component connectors