Time Allowance
| Op. No. | Operation | |
|---|---|---|
| Time Allow. | Key | |
| D 9085 00 | Electrical Check of Air Conditioning. |
TC: 86, 87
(With Multimeter MKM - 587 - A and Electronic - Kit I KM - 609)
Add:
Trouble - shooting for test step:
| 2 | |||
|---|---|---|---|
| 05 | Radiator fan motor (M4) | 1 | |
| 2 | V6 | ||
| 06 | Radiator fan motor (M11) | 1 | |
| 2 | V6, 25 DT | ||
| 37 | Radiator fan motor (M35) | ||
| 1 | |||
| 08 | Actuation of radiator fan motors | 6 | |
| 7 | V6 | ||
| 07 | Voltage supply, AC compressor clutch , (Y1) | 1 | |
| 2 | 4 Zyl., V6 | ||
| 09 | Passage check of series resistors AC fan motor with feed lines (M10) speeds 1, 2, 3 and 4, voltage supply, AC fan motor (M10) | ||
| 1 | |||
| 10 | Voltage supply, pressure assy. switch (S20.1, S20.2) | 1 | |
| 2 | 4 Zyl., V6 | ||
| 36 | Voltage supply, high pressure switch (S20.3) | 1 | |
| 2 | V6 | ||
| 22 | Voltage supply, AC fan switch (S24) |
Function of switch positions 1 to 4
| 2 | |||
|---|---|---|---|
| 12 | Voltage supply, AC switch (S101) | ||
| 1 | |||
| 14 | Voltage supply, radiator fan relay (S51) | ||
| 1 | |||
| 38 | Voltage supply, temperature end switch (Y14) | ||
| 1 | |||
| 39 | Voltage supply, temperature switch (2 speed) | ||
| 2 | |||
| 18 | Voltage supply, radiator fan relay 1st speed (K26) | ||
| 1 | |||
| 40 | Voltage supply, radiator fan relay 1st speed (K28) | ||
| 3 | |||
| 31 | Voltage supply, fan relay (K87) | ||
| 1 | |||
| 17 | Voltage supply, radiator fan relay (K52) | 2 | |
| 3 | V6 | ||
| 41 | Voltage supply, radiator fan relay (K96) | ||
| 2 | |||
| 16 | Voltage supply, radiator fan relay 2nd speed (K67) | ||
| 1 | |||
| 11 | Voltage supply, AC relay (K6) | ||
| 1 | |||
| 13 | Voltage supply, AC fan relay (K7) | ||
| 1 | |||
| 32 | Voltage supply, relay (K64) | ||
| 1 | |||
| 19 | Voltage supply, coolant temperature switch, passage check of coolant temperature switch (compressor fan) (S128) | ||
| 2 | |||
| 21 | Voltage supply, coolant temperature switch (S29) | ||
| 1 | |||
| 20 | Voltage supply, engine speed increase pressure switch (S109) | ||
| 1 | |||
| 42 | Voltage supply, relay box fan motor (M28) | ||
| 1 | |||
| 43 | Voltage supply, relay box fan motor (K49) | ||
| 2 | |||
| 44 | Voltage supply, relay box fan motor (K48) | 1 | |
| 2 | V6 | ||
| 45 | Voltage supply, compressor speed relay (K60) | 1 | |
| 2 | V6 | ||
| 46 | Voltage supply, coolant pump relay (K22) | ||
| 1 | |||
| 47 | Passage check, radiator fan series resistor (R19) | ||
| 1 | |||
| 48 | Voltage supply, coolant pump (M54) | ||
| 1 | |||
| 49 | Voltage supply, coolant pump (M57) | ||
| 1 | |||
| 27 | Remove and reinstall lower engine compartment cover |
(if required for carrying out certain test steps)
| 2 | |
|---|---|
| 24 | Remove and reinstall glove compartment |
(if required for carrying out certain test steps)
| 3 | |
|---|---|
| 26 | Remove and reinstall heater controls |
(if required for carrying out certain test steps)
| 3 |