Contents Section: Engine Controls and Fuel - 2.0L All sections

Scan Tool Output Controls Opel GT II



Scan Tool Output Controls

Engine Control Module Scan Tool Output Control

Scan Tool Output ControlAdditional Menu Selection(s)Description
A/C RelayCooling/HVAC DataAir Conditioning Compressor Clutch Enable; Air Conditioning Compressor Clutch ON
Aux. Vacuum PumpInduction DataBrake Boost Pump Control
CMP Actuator Data SystemExh. CMP Actuator Sol.Exhaust Cam Phase Solenoid Bank 1 Enable; Exhaust Cam Phase Solenoid ON
CMP Actuator SystemExhaust CMP Actuator Bank 1This function controls the exhaust camshaft position (CMP) actuator. The normal commanded state is 0 degrees. The system will INCREASE or DECREASE the exhaust camshaft timing by changing the duty cycle of the actuator in 5-degree increments up to 50 degrees. This also affects Desired Exh. CMP Angle.
CMP Actuator SystemInt. CMP Actuator Sol.Intake Cam Phase Solenoid Bank 1 Enable; Intake Cam Phase Solenoid Bank 1 ON
CMP Actuator SystemIntake CMP Actuator Bank 1This function controls the intake CMP actuator. The normal commanded state is 0 degrees. The system will INCREASE or DECREASE the intake camshaft timing by changing the duty cycle of the actuator in 5 degree increments up to 40 degrees. This also affects Desired Int. CMP Angle.
Cooling FanCooling/HVAC DataCooling Fan Speed Enable; Cooling Fan Speed
Cylinder Power BalanceMisfire DataFuel Injector Enable; Fuel Injector ON
Engine Speed ControlTAC SystemActivates the throttle activation control (TAC) system to change engine RPM. The normal commanded state is None. To enable the RPM control, all instruction on the scan tool must be completed. The system will increase or decrease the RPM within a range of 400-2,200 RPM. The set step value changes the RPM by increments of 25 RPM, 100 RPM, and 500 RPM. The system remains in the commanded state until cancelled by the scan tool.
EVAP SystemEVAP Purge SolenoidActivates the purge solenoid in 10 percent increments from 0 to 100 percent. The device control will be aborted and inhibited if the fuel tank pressure (FTP) sensor exceeds -27 mm Hg (-14 in H2O).
EVAP SystemEVAP Vent SolenoidActivates the vent solenoid. The device control will be aborted and inhibited if the FTP sensor exceeds -27 mm Hg (-14 in H2O).
EVAP SystemEVAP Purge/SealSimultaneously activates the purge solenoid in 10 percent increments from 0 to 100 percent and the vent solenoid. The device control will be aborted and inhibited if the FTP sensor exceeds -27 mm Hg (-14 in H2O).
EVAP TestEVAP DataEVAP Service Test Trigger
Fuel PumpFuel Pump RelayActivates the fuel pump relay for 2 seconds. Also turns fuel pump ON and OFF while engine is running.
Fuel SystemFuel Pressure ControlHigh Pressure Fuel Supply System Control - Demanded High Pressure
Fuel SystemFuel Pressure ControlHigh Pressure Fuel Supply System Control - MSV Control At Engine Running "High Pressure Test"
Fuel Trim EnableFuel SystemDisables the PCMs ability to learn new fuel trim parameters. The commanded states are NONE, ENABLED, DISABLED. The normal commanded state is NONE. The system remains in the commanded state until cancelled by the scan tool.
Fuel Trim ResetFuel SystemActivates the reset of fuel trim data in all fuel trim cells.
GEN L-TerminalElectrical/Theft DataGenerator L-Terminal Enable; Generator L-Terminal ON
Idle Learn ResetTAC DataIdle Adapts Reset Trigger
Loop StatusFuel Trim DataControls the system loop status. The commanded states include NONE, OPEN, or CLOSED. The normal commanded state is NONE. When commanded OPEN or CLOSED, the system remains in the commanded state until cancelled by the scan tool.
Malfunction Indicator LampEngine DataMalfunction Indicator Lamp Enable; Malfunction Indicator Lamp ON
Oil Life ResetIPC DataEngine Oil Life Remaining
Spark ControlIdle SparkEnables or disables idle spark command. When commanded ON, the idle spark will be controlled to 13 degrees before top dead center. The normal commanded state is OFF.
Special DurationsMisfire GraphicGraphs the accumulated misfires occurring in each cylinder. The scan tool allows for a reset of the misfire graph.
Starter Relay ControlElectrical/Theft DataStarter Relay Enable Starter Relay ON
TC Bypass SolenoidInduction DataTC Bypass Solenoid Command ON/OFF
TC Wastegate SolenoidInduction DataWastegate Solenoid Command 0-100%
Throttle PositionTAC SystemOperates TAC motor in 10 percent increments to open or close the throttle blade. The test operates during key ON, engine OFF.